Some stainless steels are magnetic. A magnet normally sticks to ferritic grades such as 430, martensitic grades such as 420, and duplex grades such as 2205. Annealed wrought 304 and 316 are austenitic and have little attraction to a hand magnet. Parts of those same grades can attract a magnet after forming. A magnet tells you about the part’s magnetic response, not its grade.
IN THIS ARTICLE
Which stainless steels are magnetic?
| Stainless family | Examples | Response to a hand magnet |
|---|---|---|
| Austenitic | 304, 316 | Little attraction in the annealed wrought condition; cold-worked areas can show a pull |
| Ferritic | 430 | Attracted, including in the annealed condition |
| Martensitic | 420 | Attracted, including in the annealed condition |
| Duplex | 2205 | Attracted because the structure contains ferrite as well as austenite |
Scroll horizontally to read all columns
These examples describe common grades and conditions. The family names refer to the steel’s internal structure. They do not describe the surface finish. A shiny surface does not tell you whether the steel is magnetic.
Why a magnet sticks at the bend but not on the flat
Cold work means changing the shape of metal without heating it enough for the structure to recrystallize. In austenitic stainless steel, deformation can turn part of the austenite into martensite, a phase that responds to a magnet. The amount of deformation varies across a formed part. A pressed sink can therefore show greater pull in the corners of the bowl than on the flat drainer, even when both came from the same sheet.
A weld presents a different case. Some nominally austenitic weld metal contains a small amount of ferrite. A pull at the weld and little pull beside it does not by itself mean the whole component changed grade. A local magnetic response and a grade identification answer different questions.
A measured example: the same 304 sample series after cold work
Relative magnetic permeability compares the material’s response to a magnetic field with that of a vacuum, rated 1. The Australian Stainless Steel Development Association’s Technical FAQ 3: Magnetic Effects of Stainless Steels reports the following low-field measurements for its specific 304 material:
| Cold reduction in cross-sectional area | Measured relative permeability |
|---|---|
| 0% | 1.0037 |
| 32.0% | 1.0371 |
| 65.0% | 1.540 |
Scroll horizontally to read all columns
The values are measurements for the tested 304 material, not specification limits for 304. They show that the response can rise as the same material is worked, without changing its grade. A fridge magnet is not an instrument for measuring relative permeability.
Can a magnet tell 304 from 316 or 430?
No. An annealed piece of 304 and an annealed piece of 316 can both show little pull. A magnetic pull also does not identify 430: 420 and duplex stainless can attract a magnet, and so can carbon steel. Comparing the flat and formed areas with the same magnet can help explain why attraction is uneven. It does not verify the alloy.
To establish the grade, match the heat or batch marking to traceable material records. If the material is unidentified, grade verification requires calibrated chemical analysis capable of measuring the elements that distinguish the candidates. Low-carbon variants require a method that measures carbon. The British Stainless Steel Association explains these limits in On-site methods for stainless steel grade product sorting. For the properties that distinguish two common austenitic grades, see the comparison of 304 and 316 stainless steel.